Walls & Ceilings logo
search
cart
facebook twitter linkedin youtube youtube Spotify Podcasts Apple Podcasts Spotify Podcasts Apple Podcasts
  • Sign In
  • Create Account
  • Sign Out
  • My Account
Walls & Ceilings logo
  • NEWS
  • TOPICS
    • Drywall
    • Stucco/EIFS
    • Ceilings
    • Steel Framing
    • Fireproofing
    • Plaster
    • Building Envelope
    • Insulation
    • Technology
    • Interior
    • Exterior
    • Women In Construction
  • COLUMNS
    • Up Front
    • All Things Gypsum
    • Art & Craft of Plastering
    • Stucco Stop
    • Steel Deal
    • Industry Voices
  • PRODUCTS
    • Buzz Guide
  • EVENTS
    • Industry Events
    • Webinars
    • BUILD Expo
  • MEDIA
    • Videos
    • BUILD25 Videos
    • Podcasts
    • Take our Quiz!
    • Infographics
    • SMA Home Inspector Videos
    • Image Galleries
  • EXCLUSIVE
    • Top 50 Contractors
    • Leadership Award
    • W&C Store
    • Market Research
    • eNewsletters
    • CEUs
    • Sponsor Insights
    • Custom Content & Marketing Services
    • Classifieds
    • State of the Industry
    • Industry Links
  • BLUE BOOK
    • Blue Book Online
    • Blue Book Articles
  • EMAGAZINE
    • eMagazine
    • Advertise
    • Archive Issues
  • SIGN UP!
DrywallInteriorSteel Framing

Jamb Studs: Why Are They So Challenging?

Using the right jamb studs in rough openings takes planning.

By Fernando Sesma, Mike Dolati, Steve Farkas
Jamb Studs
Images courtesy of CEMCO.
March 11, 2024

For decades now, rough openings have been challenging for not only architects and engineers, but also the contractors responsible for building them in the field. Over the years, multiple types of cold-formed steel framed headers have been developed. These range from typical box-beam headers to back-to-back headers to truss headers to non-load-bearing track headers to unique, proprietary shaped headers. Regardless of which type of header is used, the design and installation of the jamb studs supporting these headers is critical. Jamb studs are C-shaped studs that are on either side of the rough opening and help distribute the weight the header above is carrying down through the wall itself, while maintaining the integrity of the wall finish. For this article, we will focus on interior “non-load-bearing” walls.

Recent developments in the cold-formed steel framing industry, such as equivalent studs, have increased the complexity and difficulty in specifying the proper jamb studs for these rough openings. Since most of these rough openings are carrying both axial and lateral loads, they should be considered load bearing, thus disallowing the use of “EQ” products as jamb studs. Unfortunately, some architects and structural engineers do not address the interior non-load-bearing partitions in their design and allow these EQ members to be submitted, often slipping through the cracks and getting approved by plan-checkers before the project even starts, with no warning to the contractor. The use of thinner jamb studs (EQ studs are available in thicknesses ranging from 15 mils to 27 mils) may lead to failures in the wall, such as cracking of drywall, especially around and above the door frame itself.

Diagram of a typical single wide flange jamb with boxed header

Specifying Jamb Studs

Headers and jamb studs should be considered structural members, even when used as part of interior non-load-bearing partitions. Any rough opening in the wall—a door, window or large HVAC duct—will require the header to be strong enough to bear the load of the cripple studs above the header and the gypsum board attached to them. It needs a strong enough connection to transfer the load to the jamb studs. Therefore, the jamb studs should be designed for greater loads than ordinary studs. The current ICC Building Code requires a minimum lateral live load of 5 pounds per square foot if applicable, plus a dead load of 6 to 8 pounds per square foot in non-rated walls or 11 to 12 pounds per square foot for one- or two-hour fire-rated walls, to be applied to the jambs and headers. This code requirement applies axial and lateral loads on jambs and headers that might result in exceeding 100 pounds, converting the jamb studs to load-bearing members. As with all load-bearing members, these members should be designed, detailed and properly specified in the plans, as well as reinforced by the building inspectors on the job site.

Most domestic cold-formed steel framing manufacturers offer structural or load-bearing framing products ranging from a minimum thickness of 33 mils all the way up to 118 mils, with various sizes of webs, flanges and returns. Webs are available in 2 1/2 inches up to 14 inches, while flange options range from 1 3/8 inches all the way up to 3 1/2 inches. Depending upon the loads calculated by the engineer of record, some rough openings require jamb studs to be attached or fastened to each other, by either screwing or welding, to create what we know as stud packs to address the higher loads in the wall system. The larger the opening, the more likely it is that stud packs will be needed to maintain the structural integrity of the opening and the wall.

Jamb Studs
Jamb Studs
Jamb Studs

Installing Jamb Studs

So, how is one to properly specify and install jamb studs that will satisfy the load requirements for each project? Well, let us take a step back and look at three vital aspects surrounding jamb studs for all rough openings, whether they are for interior non-load-bearing or exterior load-bearing wall sections: 

  • First, all jamb studs must be designed and detailed properly based on the required loads that they are engineered to accommodate. Variables such as the depth of the wall studs, the span of the rough opening, wall height and deflection criteria, as well as any required fire and sound ratings, all contribute to the complexity of the rough opening’s design.
  • Secondly, the architect or engineer of record should specify the jamb studs for each specific project, supported by calculations confirming that the respective loads are met.
  • Lastly, once installed on-site, the jamb studs should be inspected by the local building official to ensure that they match what is specified in the details and the drawings and satisfy all local, state, regional, national and international building codes.

To help make these rough openings easier to design and detail, architects and engineers often rely upon special software, such as Simpson Strong-Tie’s CFS Designer software, as well as technical support staff from manufacturers of cold-formed steel framing products. Regardless of the way these headers and jamb studs are designed and detailed, the responsibility of properly designating all components of rough openings falls upon all of us.

KEYWORDS: doors drywall steel framing studs

Share This Story

Looking for a reprint of this article?
From high-res PDFs to custom plaques, order your copy today!

Wc1023 feat eq stud p5 author fernando sesma
Fernando Sesma is director of technical services for CEMCO. 

More information can be found at www.cemcosteel.com.

Wc0324 feat cemco p7 author mikle dolati headshot
Mike Dolati is product manager for the ProX Header at CEMCO. 

More information can be found at www.cemcosteel.com.

Wc0324 feat cemco p8 author stevefarkas
Steve Farkas is the director of business development manager for CEMCO. 

More information can be found at www.cemcosteel.com.

Recommended Content

JOIN TODAY
To unlock your recommendations.

Already have an account? Sign In

  • Walls & Ceilings Top 50

    W&C Top 50 Contractors

    Steel Framing
  • the Walls & Ceilings State of the Industry Study

    W&C State of the Industry

    The wall and ceiling industry seems to be holding...
    State of the Industry
    By: John Wyatt
  • Non-Structural Cold-Formed Steel EQ Member

    What is an “EQ” Stud?

    How do you differentiate between EQ studs?
    Steel Framing
    By: Fernando Sesma
You must login or register in order to post a comment.

Report Abusive Comment

Manage My Account
  • eMagazine Subscription
  • eNewsletter
  • Online Registration
  • Manage My Preferences
  • Subscription Customer Service

More Videos

Sponsored Content

Sponsored Content is a special paid section where industry companies provide high quality, objective, non-commercial content around topics of interest to the Walls & Ceilings audience. All Sponsored Content is supplied by the advertising company and any opinions expressed in this article are those of the author and not necessarily reflect the views of Walls & Ceilings or its parent company, BNP Media. Interested in participating in our Sponsored Content section? Contact your local rep!

close
  • Architectural Photgraphy
    Sponsored byUSG

    Evolution in Construction: USG Drywall and Suspension Systems

  • FireLITE Type X Lightweight Drywall
    Sponsored byCertainTeed

    Balancing Fire Resistance and Sustainability in Building Design

  • HITT contracting headquarters
    Sponsored byBuilding Composites LLC

    The Rise of Structural Composites

Popular Stories

Walls and Ceilings presents our annual Top 50 list of Wall & Ceiling Contractors in the country

2025’s Top Wall and Ceiling Pros — See Who Made the List

International Walls and Ceilings Contractors

Top International Walls and Ceilings Contractors

Exterior-view-of-Department-of-Labor-building-with-cloudy-sky

What Contractors Need to Know About Workforce Grant Requirements

TLPCA and Texas Contractors Launch Workforce Initiative

TLPCA and Texas Contractors Launch Workforce Initiative

Walls & Ceilings Contractor of the Year Award

Events

January 1, 2030

Webinar Sponsorship Information

For webinar sponsorship information, visit www.bnpevents.com/webinars or email webinars@bnpmedia.com.

See our full library of webinars

View All Submit An Event

Products

2025 National Painting Cost Estimator

2025 National Painting Cost Estimator

See More Products

Related Articles

  • Smart Business: The Bigger They Are, The Harder They Fall

    See More
  • construction

    This is Why it’s so Hard to Find Skilled Labor

    See More
  • Stucco is used around the world

    Stucco: So Controversial. Why?

    See More

Related Products

See More Products
  • Challenging Cover.jpg

    Challenging Applications Reference Guide - PDF

  • M:\General Shared\__AEC Store Katie Z\AEC Store\Images\Walls & Ceilings\drywall contracting 2.jpg

    Drywall Contracting

See More Products
×

Connect with the industry’s leading resource for unparalleled insights and education.

Join thousands of industry professionals today. Shouldn’t you know what they know?

JOIN NOW
  • RESOURCES
    • Advertise
    • Contact Us
    • Directories
    • Store
    • Want More
  • SIGN UP TODAY
    • Create Account
    • eMagazine
    • eNewsletter
    • Customer Service
    • Manage Preferences
  • SERVICES
    • Marketing Services
    • Reprints
    • Market Research
    • List Rental
    • Survey/Respondent Access
  • STAY CONNECTED
    • LinkedIn
    • Facebook
    • Instagram
    • YouTube
    • X
  • PRIVACY
    • PRIVACY POLICY
    • TERMS & CONDITIONS
    • DO NOT SELL MY PERSONAL INFORMATION
    • PRIVACY REQUEST
    • ACCESSIBILITY

Copyright ©2025. All Rights Reserved BNP Media.

Design, CMS, Hosting & Web Development :: ePublishing