Walls & Ceilings logo
search
cart
facebook twitter linkedin youtube youtube Spotify Podcasts Apple Podcasts Spotify Podcasts Apple Podcasts
  • Sign In
  • Create Account
  • Sign Out
  • My Account
Walls & Ceilings logo
  • NEWS
  • TOPICS
    • Drywall
    • Stucco/EIFS
    • Ceilings
    • Steel Framing
    • Fireproofing
    • Plaster
    • Building Envelope
    • Insulation
    • Technology
    • Interior
    • Exterior
    • Women In Construction
  • COLUMNS
    • Up Front
    • All Things Gypsum
    • Art & Craft of Plastering
    • Stucco Stop
    • Steel Deal
    • Industry Voices
  • PRODUCTS
    • Buzz Guide
  • EVENTS
    • Industry Events
    • Webinars
    • BUILD Expo
  • MEDIA
    • Videos
    • BUILD25 Videos
    • Podcasts
    • Take our Quiz!
    • Infographics
    • SMA Home Inspector Videos
    • Image Galleries
  • EXCLUSIVE
    • Top 50 Contractors
    • Leadership Award
    • W&C Store
    • Market Research
    • eNewsletters
    • CEUs
    • Sponsor Insights
    • Custom Content & Marketing Services
    • Classifieds
    • State of the Industry
    • Industry Links
  • BLUE BOOK
    • Blue Book Online
    • Blue Book Articles
  • EMAGAZINE
    • eMagazine
    • Advertise
    • Archive Issues
  • SIGN UP!
Stucco/EIFS

The Evolution of Continuous Insulation–Stucco Systems

CI stucco could affect methods used in future building codes.

By Chris Little
Fiberglass Z-girts (green) installed horizontally, with rainscreen (blue) and wire lath installed vertically.
July 18, 2024

Portland-cement plaster, aka stucco, continues to have a preferred position in the cladding marketplace for U.S. residential and commercial building. Recent findings from Fredonia Consulting show that stucco is applied to about 20 percent of the exterior cladding market, up 5 percent over the past three years. This demonstrates the public’s desire to have their buildings and homes constructed with stucco.

However, lath and plaster have seen a decline in certain markets where stucco or thin-veneer stone walls were poorly assembled, taking in water and then not being able to dry out. These issues are more prevalent in the eastern U.S. and along the Pacific Coast, where 20-plus inches of rainfall annually is common.

Damage to stucco cladding

Damage to stucco cladding due to moisture intrusion.

In fact, a large portion of the country is now required by code to provide a capillary break behind these “absorptive claddings” to facilitate both drainage and drying. These regulations encompass Climate Zones 1, 2 and 3, which includes most of the Southeastern U.S.; the “Marine” zone along the west coast; and the “Moist” zone, which includes areas east of Colorado. Section 703.7.3.2 of both the International Building Code and International Residential Code—water-resistive barrier requirements behind where stucco is applied to wood-based sheathings (plywood and OSB)—are divided into separate sections for dry and moist climate zones, with a 3/16-inch air space or material with high drainage efficiency required in moist climate zones. The building industry is recognizing the enhanced performance this 3/16-inch ventilated space provides, and specifications for various furring and rainscreen systems are growing in specifications and use.

6-millimeter drainage mat

6-millimeter drainage mat over sheathing for stucco and/or stone.

In 2009, the International Energy Code increased energy efficiency in 2x6 steel-framed walls in commercial construction. Normally, project teams would compensate with more batt insulation inside the wall cavity, but that approach does not consider the thermal bridging produced by the metal or wood framing. When using a correction factor, the actual thermal value is lower than design value. Therefore, the advent of continuous insulation on walls, or the adding of board insulation outside the sheathing, became the new standard CI design in the U.S., though builders in the western U.S. had been constructing homes and buildings this way earlier than 2009. Yet, with stucco applied to continuous insulation, the challenge of lath attachment started to evolve. Some of the approaches now used are described in this article.

Excerpts from the Foam Sheathing Coalition Report

Excerpts from the Foam Sheathing Coalition Report

Fasteners Used for CI Stucco

For a stucco cladding on continuous insulation, one must consider the repercussions of mechanically fastening the lath through the 1 to 4 inches of insulation and its associated deflection. Recognizing that 3/4-inch of cement-plaster weighs 10.3 pounds per square foot, that screw deflection means selecting the appropriate fastener to manage the load. Fortunately, we have guidance from the IRC/IBC on this now, in Chapter 26–Foam Plastics. Multiple tables found there, beginning with Table 2603.12.1—“Fastening Requirements Over Foam Plastic Sheathing to Support Cladding Weight for Steel Framing”—consider the deflection of the fastener based on length and load at the end of the fastener (see the illustration). 

Other factors to consider include thermal transmission through the screws, which is not defined. Yet, innovative materials like non-metallic washers or plastic-sleeved screws demonstrate limiting heat flow. Furthermore, fasteners running through the insulation system can provide a conduit for incidental moisture and must be addressed via re-direction/flashing or sealants and coatings. These solutions will continue to develop as demand for CI-stucco systems remains.

Another CI-Lath Attachment

Another common structural design for CI-stucco systems is the use of Z-furring. Z-furring is installed to allow board insulation to be sandwiched in-between the furring to reduce thermal bridging and serve as a substrate for the outboard sheathing or framing to attach the metal lath. In this design, the insulation is fitted in-between the Z-furrings to achieve CI stucco, where the lath fastening approach is more in-line with the traditional ASTM C-1063. 

For example, if the Z-furring is fastened through an exterior sheathing into the wall framing, spaced at 16 inches on-center and running vertically in line with the walls, the metal lath—sheets or rolls—would fasten perpendicular to the Z-furring with the same vertical spacing as found in the ASTM standards (7 inches o/c) down the Z-furrings. The lath’s weight selection would be determined by the “allowable span” table found in Table 1 of ASTMC-1063-23 for welded, woven or expanded metal laths. If the Z-furring is attached horizontal to the wall, i.e., perpendicular to the vertical framing members, then the lath direction changes to maintain the ASTM C-1063 for attachment—“Lath shall be installed with the long dimension at right angles to the framing members…” (Section 7.3.1.3). Currently, I am aware of only one lath product that has an approval to install lath for vertical installation on horizontal framing members (see the photo below).

Section detail for Z-furring installed under stucco

Section detail for Z-furring installed under stucco.

Fiberglass Z-girts

Fiberglass Z-girts (green) installed horizontally, with rainscreen (blue) and wire lath installed vertically.

Drainage Planes with Lath and Plaster

Drainage planes are coming, and they make sense with the right systems. These can be furring strips, drainage mats or drainable housewrap over the substrate. However, when metal lath is installed over them, the importance of full 1/4-inch furring on the lath—be it dimples or v-grooves in the sheet or bends in the wire—this feature must be present. 

In-house visual testing by my employer determined that non-furred laths over any drainage mat or wrap does not allow adequate space for plaster embedment into the lath. Furthermore, even listed “self-furred” laths, where the embossed furring becomes compromised, can make scratch-coat embedment difficult to achieve. However, that same visual testing showed welded-wire lath with uniform self-furring of 1/4-inch enhanced the ability to embed the scratch-coat on entangled mesh drainage mats. The need to embed the metal lath does not go away when a drainage plane is integrated into the CI-stucco wall.

Traditional diamond mesh lath

Traditional diamond mesh lath (left) and welded-wire lath (right) installed with a drainage mat.

In conclusion, the use of CI-stucco claddings will continue to gain preference in the marketplace. As product innovation emerges, I believe we will see refinement in the way we design and install these CI systems and, ultimately, see some of those methods prescriptive in the codes. By doing so, inclusion into codes and standards make CI stucco a viable cladding in the next generation.

KEYWORDS: CAD (Computer-Aided Design) CI (continuous insulation) EIFS lath Portland Cement Association stucco WRB (weather resistant barrier)

Share This Story

Looking for a reprint of this article?
From high-res PDFs to custom plaques, order your copy today!

Wc0123 feat clarkdietrich p5 author chris little 2022

Chris K. Little is senior product manager at ClarkDietrich. He has nearly 30 years of experience in new product development and management, and has also played an integral role in helping shape industry standards for lathing, plastering and installation of masonry and stone. He can be reached at c.k.little@clarkdietrich.com.

Recommended Content

JOIN TODAY
To unlock your recommendations.

Already have an account? Sign In

  • Walls & Ceilings Top 50

    W&C Top 50 Contractors

    Ceilings
  • the Walls & Ceilings State of the Industry Study

    W&C State of the Industry

    The wall and ceiling industry seems to be holding...
    State of the Industry
    By: John Wyatt
  • Non-Structural Cold-Formed Steel EQ Member

    What is an “EQ” Stud?

    How do you differentiate between EQ studs?
    Steel Framing
    By: Fernando Sesma
You must login or register in order to post a comment.

Report Abusive Comment

Manage My Account
  • eMagazine Subscription
  • eNewsletter
  • Online Registration
  • Manage My Preferences
  • Subscription Customer Service

More Videos

Sponsored Content

Sponsored Content is a special paid section where industry companies provide high quality, objective, non-commercial content around topics of interest to the Walls & Ceilings audience. All Sponsored Content is supplied by the advertising company and any opinions expressed in this article are those of the author and not necessarily reflect the views of Walls & Ceilings or its parent company, BNP Media. Interested in participating in our Sponsored Content section? Contact your local rep!

close
  • Architectural Photgraphy
    Sponsored byUSG

    Evolution in Construction: USG Drywall and Suspension Systems

  • FireLITE Type X Lightweight Drywall
    Sponsored byCertainTeed

    Balancing Fire Resistance and Sustainability in Building Design

  • HITT contracting headquarters
    Sponsored byBuilding Composites LLC

    The Rise of Structural Composites

Popular Stories

Walls and Ceilings presents our annual Top 50 list of Wall & Ceiling Contractors in the country

2025’s Top Wall and Ceiling Pros — See Who Made the List

International Walls and Ceilings Contractors

Top International Walls and Ceilings Contractors

Exterior-view-of-Department-of-Labor-building-with-cloudy-sky

What Contractors Need to Know About Workforce Grant Requirements

TLPCA and Texas Contractors Launch Workforce Initiative

TLPCA and Texas Contractors Launch Workforce Initiative

Walls & Ceilings Contractor of the Year Award

Events

January 1, 2030

Webinar Sponsorship Information

For webinar sponsorship information, visit www.bnpevents.com/webinars or email webinars@bnpmedia.com.

See our full library of webinars

View All Submit An Event

Products

2025 National Painting Cost Estimator

2025 National Painting Cost Estimator

See More Products

Related Articles

  • Stucco 1

    Stucco Applications on CI Systems

    See More
  • lath industry

    What’s Going on in the Lath & Plaster Industry?

    See More
  • continuous insulation

    The Continuation of Continuous Insulation

    See More

Related Products

See More Products
  • 0470872616.jpg

    Sustainable Renovation: Strategies for Commercial Building Systems and Envelope

  • Ceiling Systems Handbook 2012 cover.jpg

    Ceiling Systems Handbook

  • stuccobook_100-dpijpg.jpg

    Builder's Guide to Stucco, Lath & Plaster

See More Products

Events

View AllSubmit An Event
  • December 4, 2024

    Benefits of Today’s High-Performance Exterior Insulation and Finish Systems (EIFS) with Drainage

    Credits: 1 AIA LU/Elective; 0.1 ICC CEU; 1 IIBEC CEH; 0.1 IACET CEU On Demand This course will explore many performance and benefits of modern EIFS with drainage systems, which are used on all types of construction and as part of high-performance building enclosures.
View AllSubmit An Event

Related Directories

  • Association of the Wall and Ceiling Industry (AWCI)

    AWCI represents nearly 2,400 companies and organizations in the acoustics systems, ceiling systems, drywall systems, exterior insulation and finish systems, fireproofing, insulation, prefabrication/panelization and stucco industries. Our members are contractors, suppliers and manufacturers and those in allied trades. Our mission is connecting people in the wall and ceiling industry to innovate, grow and succeed.
×

Connect with the industry’s leading resource for unparalleled insights and education.

Join thousands of industry professionals today. Shouldn’t you know what they know?

JOIN NOW
  • RESOURCES
    • Advertise
    • Contact Us
    • Directories
    • Store
    • Want More
  • SIGN UP TODAY
    • Create Account
    • eMagazine
    • eNewsletter
    • Customer Service
    • Manage Preferences
  • SERVICES
    • Marketing Services
    • Reprints
    • Market Research
    • List Rental
    • Survey/Respondent Access
  • STAY CONNECTED
    • LinkedIn
    • Facebook
    • Instagram
    • YouTube
    • X
  • PRIVACY
    • PRIVACY POLICY
    • TERMS & CONDITIONS
    • DO NOT SELL MY PERSONAL INFORMATION
    • PRIVACY REQUEST
    • ACCESSIBILITY

Copyright ©2025. All Rights Reserved BNP Media.

Design, CMS, Hosting & Web Development :: ePublishing