Walls & Ceilings logo
search
cart
facebook twitter linkedin youtube youtube Spotify Podcasts Apple Podcasts Spotify Podcasts Apple Podcasts
  • Sign In
  • Create Account
  • Sign Out
  • My Account
Walls & Ceilings logo
  • NEWS
  • TOPICS
    • Drywall
    • Stucco/EIFS
    • Ceilings
    • Steel Framing
    • Fireproofing
    • Plaster
    • Building Envelope
    • Insulation
    • Technology
    • Interior
    • Exterior
    • Women In Construction
  • COLUMNS
    • Up Front
    • All Things Gypsum
    • Art & Craft of Plastering
    • Stucco Stop
    • Steel Deal
    • Industry Voices
  • PRODUCTS
    • Buzz Guide
  • EVENTS
    • Industry Events
    • Webinars
    • BUILD Expo
  • MEDIA
    • Videos
    • BUILD25 Videos
    • Podcasts
    • Take our Quiz!
    • Infographics
    • SMA Home Inspector Videos
    • Image Galleries
  • EXCLUSIVE
    • Top 50 Contractors
    • Leadership Award
    • W&C Store
    • Market Research
    • eNewsletters
    • CEUs
    • Sponsor Insights
    • Custom Content & Marketing Services
    • Classifieds
    • State of the Industry
    • Industry Links
  • BLUE BOOK
    • Blue Book Online
    • Blue Book Articles
  • EMAGAZINE
    • eMagazine
    • Advertise
    • Archive Issues
  • SIGN UP!
Up Front

Flashing a Window: Simple, Standard and Secure

Proper Window Flashing Is Essential for Preventing Water Intrusion. While Various Methods Exist, Following Industry Standards and Keeping the Process Simple Helps Ensure Durability, Reduce Installation Errors, and Minimize Construction Risks.

By Mark Fowler
Up Front: A Walls & Ceilings editorial Column by Mark Fowler
Background Image: uschools / iStock / Getty Images Plus via Getty Images. Composition by James Hoener
April 21, 2025

Windows and doors are unique elements of a building’s envelope, as they penetrate the entire wall assembly, connecting the interior and exterior. Unlike small penetrations such as hose bibs or electrical outlets, windows are subject to both interior and exterior design pressures. To understand these pressures, consider how a slightly open back door can slam shut due to the differential pressure or vacuum created between indoor and outdoor spaces. In tall buildings, this effect—known as the “stack effect”—can be even more pronounced. Wind speed, local terrain, and the size and placement of window openings all influence these forces. To withstand them, windows must be tested and rated for design pressure (DP) to ensure durability and performance.

While energy efficiency is crucial, the primary concern for subcontractors is water intrusion. Selecting a properly rated window is only part of the equation; the transition from the window frame to the cladding must also be correctly sealed to prevent leaks.

Types of Windows and Flashing Approaches

Windows generally fall into two categories for flashing: “flanged” and “non-flanged”:

Flanged Windows: The most common type in residential and light commercial construction, these windows are typically made from PVC and feature a nailing flange for straightforward installation.

Non-Flanged Windows: Often found in metal-framed storefronts and some wood-framed designs, these windows require a different approach to flashing.

Regardless of window type, sealing the perimeter between the frame and cladding is essential. There are numerous flashing methods, ranging from simple to highly complex, with differing opinions on the best approach.

Keep it Simple

A straightforward approach often yields the best results. The KISS principle (“Keep It Simple, Stupid”) applies here. Industry standards such as those from ASTM, AAMA or SMA provide reliable guidelines for flashing windows. Empirical evidence and lab testing confirm that even basic flashing methods can effectively prevent water from reaching the sheathing and wall cavity.

Through years of inspections and experience in defect litigation, common causes of water leaks have become clear: either the window itself is defective, or the flashing installation is faulty. Field water tests based on AAMA’s Method A or B often reveal that improperly rated windows fail under expected conditions. More frequently, installation failures result from reverse laps in the flashing process, rather than product defects or inadequate upgrades. Forensic investigations frequently uncover misinterpretations of flashing procedures, leading to confusion among both engineers and installers. Given the pressure to meet schedules and budgets, such failures can seem inevitable.

Minimize Risk

Risk avoidance is a major concern in construction today. A conversation with an envelope consultant once highlighted this issue: When I pointed out that his complex multi-step flashing process was prone to installation errors, he responded, “If it leaks, it won’t be my fault.” His focus was on liability avoidance rather than ensuring a watertight envelope. This mindset shifts the burden to installers rather than serving the client’s best interests.

To mitigate risk, follow established industry standards and manufacturer guidelines. Adding unnecessary layers and complexity may seem like a safer approach, but it can introduce more opportunities for installation errors. Installers should also take responsibility for identifying design flaws or conflicts with best practices. If a specified method is overly complicated, proposing a recognized alternative—one that meets code and is legally defensible—can protect both the installer and the project.

At the end of the day, risk reduction is a shared responsibility. By simplifying processes and ensuring clarity in execution, both designers and installers can contribute to long-term building performance and durability.
KEYWORDS: building codes building performance energy efficiency flashing moisture windows

Share This Story

Looking for a reprint of this article?
From high-res PDFs to custom plaques, order your copy today!

Headshots fowler

Mark Fowler joined Walls & Ceilings as editorial director in 2006. Fowler grew up in the construction business and has held a number of positions in different companies and associations. He spent 11 years with the Northwest Wall and Ceiling Bureau before moving to his position with Soltner Group Architects in Seattle. Fowler is currently the executive director of the Stucco Manufacturers Association. He can be reached at Mark@markfowler.org.

 

Recommended Content

JOIN TODAY
To unlock your recommendations.

Already have an account? Sign In

  • Walls & Ceilings Top 50

    W&C Top 50 Contractors

    Steel Framing
  • the Walls & Ceilings State of the Industry Study

    W&C State of the Industry

    The wall and ceiling industry seems to be holding...
    State of the Industry
    By: John Wyatt
  • Non-Structural Cold-Formed Steel EQ Member

    What is an “EQ” Stud?

    How do you differentiate between EQ studs?
    Steel Framing
    By: Fernando Sesma
You must login or register in order to post a comment.

Report Abusive Comment

Manage My Account
  • eMagazine Subscription
  • eNewsletter
  • Online Registration
  • Manage My Preferences
  • Subscription Customer Service

More Videos

Sponsored Content

Sponsored Content is a special paid section where industry companies provide high quality, objective, non-commercial content around topics of interest to the Walls & Ceilings audience. All Sponsored Content is supplied by the advertising company and any opinions expressed in this article are those of the author and not necessarily reflect the views of Walls & Ceilings or its parent company, BNP Media. Interested in participating in our Sponsored Content section? Contact your local rep!

close
  • Architectural Photgraphy
    Sponsored byUSG

    Evolution in Construction: USG Drywall and Suspension Systems

  • FireLITE Type X Lightweight Drywall
    Sponsored byCertainTeed

    Balancing Fire Resistance and Sustainability in Building Design

  • HITT contracting headquarters
    Sponsored byBuilding Composites LLC

    The Rise of Structural Composites

Popular Stories

Walls and Ceilings presents our annual Top 50 list of Wall & Ceiling Contractors in the country

2025’s Top Wall and Ceiling Pros — See Who Made the List

International Walls and Ceilings Contractors

Top International Walls and Ceilings Contractors

Exterior-view-of-Department-of-Labor-building-with-cloudy-sky

What Contractors Need to Know About Workforce Grant Requirements

TLPCA and Texas Contractors Launch Workforce Initiative

TLPCA and Texas Contractors Launch Workforce Initiative

Walls & Ceilings Contractor of the Year Award

Events

January 1, 2030

Webinar Sponsorship Information

For webinar sponsorship information, visit www.bnpevents.com/webinars or email webinars@bnpmedia.com.

See our full library of webinars

View All Submit An Event

Products

2025 National Painting Cost Estimator

2025 National Painting Cost Estimator

See More Products

Related Articles

  • WC0522-CLMN-Up-Front-p1FT-Mark-Fowler-1170x658.jpg

    What You Need to Know About Flashing a Window

    See More
  • Stucco Cladding: A Modern Approach With Stone Wool

    Stucco Cladding: A Modern Approach With Stone Wool

    See More
  • Up Front

    What Makes a Successful Company

    See More

Related Products

See More Products
  • smo-green-standard-edition-log-book.png

    Log Book - Green Standard Edition

  • building codes illustated.jpg

    Building Codes Illustrated: A Guide to Understanding the 2021 International Building Code, 7th Edition

  • bim 3e.jpg

    BIM Handbook: A Guide to Building Information Modeling for Owners, Designers, Engineers, Contractors, and Facility Managers, 3rd Edition

See More Products

Events

View AllSubmit An Event
  • December 4, 2024

    Stucco: Beyond the Basics

    Credits: 1 AIA LU/HSW;  0.1 ICC CEU; 1 IIBEC CEH;  0.1 IACET CEU On Demand This course will cover lath, flashing and cement plaster (stucco) with a focus on successful designs as well as failures from field investigations that we should all be learning from. Designers will be shown options that are proven to work as well as options that repeatedly present problems. Designers and contractors will learn about industry standards and how they can help or be used to hurt you.
View AllSubmit An Event

Related Directories

  • MFM Building Products

    Waterproofing Membranes: MFM manufactures a full line of self-adhering waterproofing membranes including window and door flashing tapes, construction, joint and roofing membranes.
×

Connect with the industry’s leading resource for unparalleled insights and education.

Join thousands of industry professionals today. Shouldn’t you know what they know?

JOIN NOW
  • RESOURCES
    • Advertise
    • Contact Us
    • Directories
    • Store
    • Want More
  • SIGN UP TODAY
    • Create Account
    • eMagazine
    • eNewsletter
    • Customer Service
    • Manage Preferences
  • SERVICES
    • Marketing Services
    • Reprints
    • Market Research
    • List Rental
    • Survey/Respondent Access
  • STAY CONNECTED
    • LinkedIn
    • Facebook
    • Instagram
    • YouTube
    • X
  • PRIVACY
    • PRIVACY POLICY
    • TERMS & CONDITIONS
    • DO NOT SELL MY PERSONAL INFORMATION
    • PRIVACY REQUEST
    • ACCESSIBILITY

Copyright ©2025. All Rights Reserved BNP Media.

Design, CMS, Hosting & Web Development :: ePublishing